Technical data, Installation, Positioning – AEG SCS81800F0 User Manual
Page 38: Electrical connection, Door reversibility
TECHNICAL DATA
Dimension of the recess
Height
1780 mm
Width
560 mm
Depth
550 mm
Rising Time
21 h
The technical information are situated in the rating plate on the internal left side of the
appliance and in the energy label.
INSTALLATION
WARNING!
Read the "Safety Information" carefully for your safety and correct operation of the ap-
pliance before installing the appliance.
Positioning
Install this appliance at a location where the ambient temperature corresponds to the
climate class indicated on the rating plate of the appliance:
Climate class
Ambient temperature
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
Electrical connection
Before plugging in, ensure that the voltage and frequency shown on the rating plate cor-
respond to your domestic power supply.
The appliance must be earthed. The power supply cable plug is provided with a contact
for this purpose. If the domestic power supply socket is not earthed, connect the appli-
ance to a separate earth in compliance with current regulations, consulting a qualified
electrician.
The manufacturer declines all responsibility if the above safety precautions are not ob-
served.
This appliance complies with the E.E.C. Directives.
Door reversibility
The door of the appliance opens to the right. If you want to open the door to the left, do
these steps before you install the appliance:
38
Technical data