Konica Minolta bizhub 654e User Manual
Page 41
bizhub 754e/654e
2-28
2.8
Overwrite All Data Function
2
3
Select the desired mode and touch [Delete].
4
A confirmation message appears. Select [Yes] and touch [OK].
5
Make sure that a message appears prompting you to turn OFF and then ON the main power switch.
Now, turn OFF and then turn ON the main power switch.
% Check that all data has been overwritten and erased properly. Data is not erased properly if an error
occurs during the procedure. For details, contact your Service Representative.
% When the main power switch is turned off, then on again, wait at least 10 seconds to turn it on after
turning it off. if there is no wait period between turning the main power switch off, then on again, the
machine may not function properly.
Here is the sequence, through which the main power switch and sub power key are turned on and
off:
Turn off the sub power key ö Turn off the main power switch ö Turn on the main power switch ö
Turn on the sub power key
% After the main power switch has been turned on, quickly turn it off and give the machine to the Ser-
vice Engineer. If the Overwrite All Data function is executed by mistake, contact the Service Engi-
neer. For details, contact your Service Representative.