Installing or removing the rear backplane/cage kit – Lenovo ThinkServer RD550 User Manual
Page 109

Installing or removing the rear backplane/cage kit
The rear backplane/cage kit enables you to install up to two 2.5-inch hard disk drives for your server models
with 3.5-inch drives. You can purchase a rear backplane/cage kit from Lenovo.
Installing the rear backplane/cage kit
Attention: Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii and “Guidelines” on page 61.
Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
Note: Use any documentation that comes with the rear backplane/cage kit and follow those instructions in
addition to the instructions in this topic.
To install the rear backplane/cage kit, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. Prepare your server. See “Removing or extending the server from the rack cabinet” on page 63.
3. Remove the server cover. See “Removing the server cover” on page 63.
4. Locate the rear backplane/cage kit bay. See “Server components” on page 25.
5. Lift the metal shield that protects the rear backplane/cage kit bay. Store the shield in case that you later
remove the kit and need the shield to cover the bay.
Figure 63. Removing the protective shield for the rear backplane/cage kit bay
6. Touch the static-protective package that contains the components of the rear backplane/cage kit to any
unpainted surface on the outside of the server. Then, take the components out of the package.
7. Install the rear backplane to the cage. See “Replacing the rear backplane” on page 97.
95