beautypg.com

Variety steamer, Operation, Operator controls – Antunes, AJ VS-200aSb User Manual

Page 10

background image

10

Variety SteaMer

P/N 1010649 Rev. E 03/07

OperatIOn

Operator controls

rOcKer swItcH (pOwer On/Off)

When the Rocker switch is in the ON position, the

control board is activated and the green light on the

front panel lights up. a thermostat senses generator

temperature. if the generator temperature is below

30° f (176° c), power is applied to the generator until

setpoint is reached. the generator is constantly moni-

tored and power is regulated to maintain temperature

setpoint of 380° f (193° c).

YellOw anD Green lIGHts

the green light comes on when the Rocker switch

(Power On/Off) is turned on. the green light is not lit

during the steaming cycle.

the yellow light comes on during the steaming cycle.

When the steaming cycle is complete, the yellow light

turns off, and an audio alarm sounds for 3 seconds.

cOntrOl KnOb

the control knob setting determines the length of the

steaming cycle. Each number on the panel behind the

knob represents a ten second interval (1=10 sec; 2=20

sec; 3=30 sec; etc.) up to 130 seconds.

Example: During the steaming cycle, with the control

knob set to 3, the solenoid valve opens once every 10

seconds, applying 3 total shots of water that is con-

verted immediately into steam for the product.

nOte: each shot of steam is approximately 3/4 oz.

(25 milliliters) of water.

Operate swItcH

When the operate button is pressed and released, Line

Voltage is supplied to the solenoid valve, the solenoid

valve opens, and water sprays onto the heated steam

generator. the water flashes immediately into live

steam and is forced up through the black Manifold

Plate orifices.

lOcK leVer

When in the full forward (towards operator) position,

the lock lever secures the black Manifold Plate onto

the steam generator. Moving the lock lever to the full

rearward position unlocks the black Manifold Plate,

allowing it to be removed for cleaning or servicing.

POWER

1

2

3

4

5

6

7

8

9

10

11

12

13

READY

STEAM

Green

Light

Yellow

Light

Operate

Switch

Lock Lever

Knob

Control

Knob

Rocker Switch

(power on/off)

Audio

Signal

figure 3. Operating controls

Lock Lever Knob

Locked Position

figure 4. lock lever

HI-lImIt tHermOstat

if the generator should overheat for any reason, the

Hi-Limit thermostat opens (trips) and cuts off power to

the generator. to reset this Hi-Limit, turn the unit off,

unplug the power cord, disconnect the rear water line

quick disconnect insert, and allow the unit to cool for 4

minutes. Place unit upside down and remove the four

(4) control Panel screws (figure 4). carefully lift the

control Panel upward and lay it on its side. fully press

the red Hi-Limit Reset button. Reassemble the unit. if

the Hi-Limit requires continuous resetting, contact your

authorized service agency.