1000base-t pin assignments, Table b-2, 1000base-t mdi and mdi-x port pinouts – Accton Technology ES3628EA User Manual
Page 49: Figure b-3, Crossover wiring

B-3
Twisted-Pair Cable and Pin Assignments
B
Figure B-3 Crossover Wiring
1000BASE-T Pin Assignments
All 1000BASE-T ports support automatic MDI/MDI-X operation, so you can use
straight-through cables for all network connections to PCs or servers, or to other
switches or hubs.
The table below shows the 1000BASE-T MDI and MDI-X port pinouts. These ports
require that all four pairs of wires be connected. Note that for 1000BASE-T
operation, all four pairs of wires are used for both transmit and receive.
Use 100-ohm Category 5, 5e or 6 unshielded twisted-pair (UTP) or shielded
twisted-pair (STP) cable for 1000BASE-T connections. Also be sure that the length
of any twisted-pair connection does not exceed 100 meters (328 feet).
Table B-2 1000BASE-T MDI and MDI-X Port Pinouts
Pin
MDI Signal Name
MDI-X Signal Name
1
Bi-directional Data One Plus (BI_D1+)
Bi-directional Data Two Plus (BI_D2+)
2
Bi-directional Data One Minus (BI_D1-)
Bi-directional Data Two Minus (BI_D2-)
3
Bi-directional Data Two Plus (BI_D2+)
Bi-directional Data One Plus (BI_D1+)
4
Bi-directional Data Three Plus (BI_D3+)
Bi-directional Data Four Plus (BI_D4+)
5
Bi-directional Data Three Minus (BI_D3-)
Bi-directional Data Four Minus (BI_D4-)
6
Bi-directional Data Two Minus (BI_D2-)
Bi-directional Data One Minus (BI_D1-)
7
Bi-directional Data Four Plus (BI_D4+)
Bi-directional Data Three Plus (BI_D3+)
8
Bi-directional Data Four Minus (BI_D4-)
Bi-directional Data Three Minus (BI_D3-)
White/Orange Stripe
Orange
White/Green Stripe
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
10/100BASE-TX Crossover Cable
End A
End B
Green
Blue
White/Blue Stripe
Brown
White/Brown Stripe