Appendix A: Troubleshooting

Diagnosing Switch Indicators

Diagnosing Power Problems with the LEDs

The Power and RPS LEDs work in combination to indicate power status as follows.

Power and Cooling Problems

If the power indicator does not turn on when the power cord is plugged in, you may
have a problem with the power outlet, power cord, or internal power supply.
However, if the unit powers off after running for a while, check for loose power
connections, power losses or surges at the power outlet, and verify that the fans on
the unit are unobstructed and running prior to shutdown. If you still cannot isolate the
problem, then the internal power supply may be defective.

Table A-1 Troubleshooting Chart

Symptom

Action

Power LED is Off

• Power supply is disconnected.
• Check connections between the switch, the power cord, and the wall outlet.
• Contact your dealer for assistance.

Power LED is Amber

• Internal power supply has failed. Contact your local dealer for assistance.

Diag LED is Amber

• Power cycle the switch to try and clear the condition.
• If the condition does not clear, contact your dealer for assistance.

Link LED is Off

• Verify that the switch and attached device are powered on.
• Be sure the cable is plugged into both the switch and corresponding device.
• Verify that the proper cable type is used and its length does not exceed specified

limits.

• Check the adapter on the attached device and cable connections for possible

defects. Replace the defective adapter or cable if necessary.

Table A-2 Power/RPS LEDs

Power LED

RPS LED

Status

Green

Green

Internal power functioning normally; RPS is present.

Green

Amber

Internal power functioning normally; RPS plugged in but faulty.

Green

Off

Internal power functioning normally; RPS not plugged in.

Amber

Green

Internal power faulty; RPS delivering power.

Off

Off

Both internal power and RPS unplugged or not functioning.