Optional redundant power supply, Power supply receptacles, Table 1-2 – Accton Technology ES3628EA User Manual
Page 20: System status leds, Figure 1-3, System leds, Figure 1-4

Introduction
1-4
1
Figure 1-3 System LEDs
Optional Redundant Power Supply
The switch supports an optional Redundant Power Supply (RPS) that can supply
power to the switch if the internal power supply should fail.
Power Supply Receptacles
There are two power receptacles on the rear panel of the switch. The standard
power receptacle is for the AC power cord. The receptacle labeled “RPS” is for the
optional Redundant Power Supply (RPS).
Figure 1-4 Power Supply Receptacles
Table 1-2 System Status LEDs
LED
Condition
Status
Power
On Green
Internal power is operating normally.
On Amber
Internal Power supply fault.
Off
Power off or failure.
Diag
Flashing Green
System self-diagnostic test in progress.
On Green
System self-diagnostic test successfully completed.
On Amber
System self-diagnostic test has detected a fault.
Alternating
Amber & Green
Fan failure or system overheated.
RPS
On Green
Redundant power supply is receiving power.
On Amber
Fault in redundant power supply (including thermal or fan).
Off
There is no redundant power supply currently attached.
System Indicators
RPS
DC
12V 13A
100-240V~
50-60Hz 0.6A
Redundant Power Socket
Power Socket