beautypg.com

TotalPond PF1200UV User Manual

Page 2

background image

2

grounding plug. The plug must be plugged into an appropriate outlet that is installed and grounded in
accordance with all local codes and ordinances.

CAUTION

UV light may cause irritation to the skin and/or eyes. Avoid exposure.

DANGER – ULTRAVIOLET RADIATION – Diconnect Power Before Replacing Lamp.

Prolonged or repeated exposure to UV light may have adverse physical effects including, severe
damage to your skin and eyes. Seek immediate medical attention for overexposure to UV radiation.

Keep the cord away from high temperatures or other heat sources.

Do not lift the light or the transformer by its power cord.

This light assembly has not been investigated for use in swimming pools or hot tubs.


IMPORTANT NOTES

This product is designed to prohibit its operation unless it is fully assembled with the lamp base
screwed completely into the housing.

UV rays are harmful to your eyes and skin. The indicator portal will remove the harmful effects of the UV
light but still allow you to see the bulb operating.

Do not attempt to operate this product unless the lamp is completely assembled within the light
housing.

This product conforms to the Code of Federal Regulations (CFR) requirements including, Title 21,
Chapter 1, Subchapter J, Radiological Health.






PREPARATION

Before beginning assembly

of product, make sure all parts are present. Compare parts with package

contents list and diagram above. If any part is missing or damaged, do not attempt to assemble, install or
operate the product. Contact customer service for replacement parts.

Estimated Assembly Time: 20 minutes

Tools required for assembly: hacksaw

.

Specifications

Lamp Voltage

60V

Lamp Current

0.2A

Lamp Power

9 W

Rated Frequency

60 Hz

UV Irradiance

35 µW/cm

2

Bulb Life

8000 hours

Bulb Model Number

UVRB

UV Wave Length

UV(C) · 254 nm