Unit connectors – Axis Communications 262+ User Manual
Page 9

AXIS 262+ Installation Guide
Page 9
ENGLISH ENGLISH
Unit Connectors
RS-232 connector - For the connection of a UPS (Uninterruptible Power Supply) unit. For
approved models, see the AXIS 262+ User’s Manual.
Network connector- RJ-45 Ethernet connector. Using shielded cables is recommended.
I/O terminal connector - The 9-pin I/O terminal connector provides the interface to four
digital outputs, four digital photo-coupled inputs and Ground.
Pin
Event
Function
State
Specifications
Notes
Alarm
input
1
Must not be
exposed to volt-
ages greater
than 5V DC
Connect to GND
to activate, or
leave floating
(or uncon-
nected) to deac-
tivate.
2
3
4
Output
5
Alarm record-
ing starts/
stops
If any of the
sources start or
stop alarm
recording, AXIS
262+ outputs
the status
High/
Low
Max load =
100mA
Max voltage =
24V DC
(to the transis-
tor)
Uses an open-
collector NPN
transistor with
the emitter con-
nected to the
GND pin. If used
with an exter-
nal relay, a
diode must be
connected in
parallel with the
load, for protec-
tion against
voltage tran-
sients.
6
Camera lost
If any of the
sources looses a
connection with
a camera, AXIS
262+ outputs
the status
High
7
Hard disk
error
If a hard disk
error occurs, it
outputs the sta-
tus
High
8
Hard disk full
If the hard disk
is full it outputs
the status
High
GND
9
Ground
Pin layouts