Caution – Duff-Norton SK6405-100 User Manual
Page 4
with a single pin through one clevis end, secure it to its
load with a second clevis pin, and then use the appropri-
ate wiring diagram (AC or DC, Figure 2-1 or 2-2) to con-
nect the actuator to your power source.
2-2.
Avoid using a low voltage supply for the actuator,
All wiring, switches, and other electrical components
must be of sufficient capacity to carry the required cur-
rent.
2-3.
The translating tube is not keyed, and must be
restrained from rotating.
2-4.
The axes of the clevis pins should be parallel so
that the actuator can pivot without binding. A few drops
of oil should be applied to the clevis pins on installation
and periodically thereafter.
2-5.
External wires for customer hookup are color coded
as to direction of travel (see wiring diagrams, Figure 2-1
or 2-2).
SECTION I
DIMENSIONS AND SPECIFICATIONS
SECTION II
INSTALLATION
FIGURE 1-1
FIGURE 2-1
FIGURE 2-1
Note: Dimensions are subject to change without snotice.
To protect the actuator and prevent damage from
overtravel, it is recoommended that travel limiting
switches be incorporated in the installation.
CAUTION
6405-100 10/10/06 11:50 AM Page 4