Model information – Duff-Norton EM1010-100 (TMD02) User Manual
Page 3
1-3 Specifications
Stroke Lengths:
Duty Cycle:
Input Power:
Ambient Temperature:
Motor Protection:
Overload Protection:
Limit Switched (opt.):
End Play:
Static Load:
Mounting:
2, 4, 6, 8, 10, & 12 inch. Special lengths on application.
25% max. on time at rated load and 25˚C ambient.
12 or 24 VDC, depending on model.
-20˚F to 120˚F (-29˚C to 50˚C)
External fusing by installer recommended; 8 amp rating, standard time response.
Limit switch models include internal fusing.
By motor fusing (see above).
Independently adjustable, magnetic reed switches with a control relay.
.060” max.
300 lbs. Max.
Keyed translating tube with hole for .250” pin, each end. #10-32 axial thread in
translating tube end for optional rod end.
MODEL INFORMATION
1-4 Dimensions
TMD01-1406-stroke
100 lb. Non-Limit Switch 12VDC
TMD01-1906-stroke
100 lb. Limit Switch 12VDC
TMD01-2406-stroke
100 lb. Non-Limit Switch 24VDC
TMD01-2906-stroke
100 lb. Limit Switch 24VDC
TMD02-1406-stroke
250 lb. Non-Limit Switch 12VDC
TMD02-1906-stroke
250 lb. Limit Switch 12VDC
TMD02-2406-stroke
250 lb. Non-Limit Switch 24VDC
TMD02-2906-stroke
250 lb. Limit Switch 24VDC
100 Lb.
250 Lb.
Model
100 Lbs.
200 Lbs.
A
Stroke + 4.75
Stroke +5.00
B
2.15
3.18
C
.88
1.73
D
2.54
2.85
E
.30
.42
F
.25
.33
G
.63
.75
EM-1010-100_0706 7/31/07 2:40 PM Page 2