Specifications / 4. design and function, Specifications, Design and function – WIKA 55 User Manual
Page 10
GB
11583747.03 10/2013 GB/D/F/E
10
WIKA operating instructions models 53, 54, 55 (ATEX)
3. Specifications
Specifications
Model 53
Model 54
Model 55
Measuring element
Bimetal coil
Nominal size
3", 5"
63, 80, 100, 160 63, 100, 160
Instrument version
■
Model A5x
■
Model R5x
■
Model S5x
Back mount (axial)
-
Lower mount (radial)
Back mount, housing can rotate and swivel
Permissible ambient
temperature
-20 ... +60 °C max.
-50 ... +60 °C
Working pressure
■
Continuous load (1 year)
■
Short term (max. 24 h)
Measuring range (EN 13190)
Scale range (EN 13190)
Case, ring
Stainless steel 1.4301 (304)
Stem, process connection Stainless steel 1.4571 (316Ti)
Ingress protection
IP 65 per EN 60529 / IEC 529
IP 66, liquid-filled
For further specifications see WIKA data sheet TM 53.01, TM 54.01
or TM 55.01 and order documentation.
4. Design and function
4.1 Description
The bimetal thermometers of this series are intended for installation in
pipelines, vessels, plant and machinery.
Sheath and case are made of stainless steel.
To allow fitting to the process, different installation lengths and
process connections are available.
Through the high protection class of the thermometer (IP 65) and its
liquid damping, operation under vibration conditions is possible.