beautypg.com

Specifications / 4. design and function, Specifications, Design and function – WIKA 55 User Manual

Page 10

background image

GB

11583747.03 10/2013 GB/D/F/E

10

WIKA operating instructions models 53, 54, 55 (ATEX)

3. Specifications

Specifications

Model 53

Model 54

Model 55

Measuring element

Bimetal coil

Nominal size

3", 5"

63, 80, 100, 160 63, 100, 160

Instrument version

Model A5x

Model R5x

Model S5x

Back mount (axial)

-

Lower mount (radial)

Back mount, housing can rotate and swivel

Permissible ambient

temperature

-20 ... +60 °C max.

-50 ... +60 °C

Working pressure

Continuous load (1 year)

Short term (max. 24 h)

Measuring range (EN 13190)

Scale range (EN 13190)

Case, ring

Stainless steel 1.4301 (304)

Stem, process connection Stainless steel 1.4571 (316Ti)

Ingress protection

IP 65 per EN 60529 / IEC 529

IP 66, liquid-filled

For further specifications see WIKA data sheet TM 53.01, TM 54.01

or TM 55.01 and order documentation.

4. Design and function

4.1 Description

The bimetal thermometers of this series are intended for installation in

pipelines, vessels, plant and machinery.

Sheath and case are made of stainless steel.

To allow fitting to the process, different installation lengths and

process connections are available.

Through the high protection class of the thermometer (IP 65) and its

liquid damping, operation under vibration conditions is possible.

3. Specifications / 4. Design and function

This manual is related to the following products: