6. Commissioning, operation
Lemosa connector,
(male) on cable
Binder connector,
(male) on cable
(threaded plug connection)
Single
thermocouple
Colour coding of
the wire ends see
table
Cable
Dual
thermocouple
Colour code of cable
Positive and negative terminal are marked. Two
miniature size thermo connectors are used with
dual thermocouples.
Thermo connector
Type of sensor Standard
Positive terminal
Negative terminal
K
DIN EN 60584
green
white
J
DIN EN 60584
black
white
E
DIN EN 60584
violet
white
T
DIN EN 60584
brown
white
N
DIN EN 60584
pink
white