Permissible temperature

Ambient:

-20 ... +60 °C

Medium:

+150 °C maximum

When autoclaving: max. 134 °C, 20 minutes

Temperature effect

When the temperature of the measuring system deviates from the

reference temperature (+20 °C): max. ±2 %/10 K of full scale value

(typically ±1 %/10 K of full scale value)

Ingress protection

IP 68 per EN 60529 / IEC 529
For further specifications see WIKA data sheet PM 04.15 and the

order documentation.

4. Design and function

4.1 Description

The model PG43SA pressure gauge is designed especially for the

requirements of the food and beverage, pharmaceutical and biotech-

nology industries.

The PG43SA pressure gauge is particularly suitable for the special

conditions of CIP/SIP cleaning processes, e.g. thanks to chemical

stability towards cleaning liquids and high temperatures. The flush

metal diaphragm element is directly welded to the process connection.

This guarantees a crevice-free connection of process connection and

diaphragm element; additional internal sealings are not required.

4.2 Scope of delivery

Cross-check scope of delivery with delivery note.

3. Specifications / 4. Design and function