Flex Liners to the Appliance Connector using

four sheet metal screws each. (Figure 9) In

either case, make sure the Flex Liners do not

sag behind the appliance. Finally, move the

appliance into its appropriate place.

GENERAL MAINTENANCE

Conduct an inspection of the venting system

semiannually. Recommended areas to inspect are

as follows:

1. Check areas of the Venting System which are

exposed to the elements for corrosion. These

will appear as rust spots or streaks, and in

extreme cases, holes. These components should

immediately be replaced.

2. Remove the cap and remove any bird nests, or

other foreign material.

3. Check for evidences of excessive condensate,

such as water droplets forming in the liners, and

subsequently dripping out at joints. Continuous

condensate can cause corrosion of caps, liners, and

fittings. It may be caused by having exterior portions

of the system being exposed to cold weather.