Vertical installation – DuraVent Venting System For Direct Vent Pro User Manual
Page 12

12
Figure 12
available in both 1-piece and
4-piece versions.
Installing the 1-piece counter
flashing: Center the counter flashing on
the wall around the framed penetration.
Secure to the wall using the screws
provided or other necessary connector
depending on the wall material. Attach
the Horizontal Cap to the Counter
Flashing by lining up the holes in the
cap with the holes in the Counter
Flashing. Secure using the 4 long
screws provided with the cap (Fig. 12).
Installing the 4-piece Counter
Flashing: Attach the 4 pieces together
starting with the top piece and work
counter-clockwise.
Secure the 4 pieces together before
mounting Counter Flashing to the wall.
Mount the assembled Counter Flashing
on the wall, centered around the framed
wall penetration.
Depending on wall construction, use
screws or other suitable connector
through the flanged edges to secure
Counter Flashing to the wall.
Seal around the perimeter of the
Counter Flashing using non-hardening
waterproof sealant to help ensure a
weather tight seal.
(4) If the optional copper version of
Horizontal Termination Cap is installed,
use an appropriate non-combustible
material to avoid direct contact between
the galvanized and copper metals to
prevent possible galvanic reaction.
VERTICAL INSTALLATION
Step 1. Check the appliance
manufacturer’s installation instructions
for required clearances (air spaces) to
combustibles when passing through
CUT EXTERIOR
OF WALL AS
REQUIRED IN
ASSEMBLE VINYL
STANDOFF/COUNTER
SPECIFIC ORDER
TABLE 1
FLASHING IN
VINYL SIDING,
STUCCO OR OTHER
SIDING MATERIAL
1
2
3
4
HOT
HOT
HOT
4 PC. KIT
ASSEMBLED IN
SEQUENCIAL
ORDER
FASTEN THE
4 CORNERS
THROUGH
THE HOLES
PROVIDED
FASTEN TERMINATION
TO ASSEMBLY
THROUGH THE
HOLES PROVIDED
SQU
ARE
ROUND
CAP
SCONCE
CAP
CAP
1st
2nd
3rd
4th
HOT
PLUMB AND LEVEL
ENSURE ASSEMBLY IS
GAPS
& SCREWS
SEAL ALL
CONNECT TO WALL
AS REQUIRED