Connecting the fc-4046 video multicoder, Table 5: dipswitch standard definitions – Kramer Electronics FC-4046 User Manual
Page 11

Connecting the FC-4046 Video MultiCoder®
9
6.2 Dipswitch Settings
Configure the
FC-4046 unit by setting the 8 dipswitches, as Figure 4 and
Table 4 define:
Figure 4: Dipswitches (Factory Default)
Table 4: Dipswitch Settings
Dipswitch
Set as follows:
1 PEDESTAL
1
ON for pedestal; OFF for no pedestal (7.5 IRE offset selection for NTSC)
2 STANDARD 1
3 STANDARD 2
4 STANDARD 3
See Table 5 (for selecting the INPUT video standard)
5 AUTO
2
ON for multi-standard; OFF for user-selected (fixed) standard
6 H SYNC
ON for Horizontal sync on Hs/Cs BNC; OFF for composite sync output
7 BAR
ON for machine to operate as a 75% color bar generator
3
8 AGC
4
ON for automatic gain control; OFF for fixed gain
Table 5: Dipswitch Standard Definitions
Standard
DIP Standard 1
DIP Standard 2 DIP Standard 3 DIP Auto
2
Auto Detection
OFF
OFF
OFF
ON
PAL
OFF
OFF
OFF
OFF
NTSC
OFF
OFF
ON
OFF
SECAM
OFF
ON
OFF
OFF
PAL-M
OFF
ON
ON
OFF
PAL-Nc
ON
OFF
OFF
OFF
PAL-60
ON
OFF
ON
OFF
NTSC 4.43
ON
ON
OFF
OFF
1 NTSC offsets the black level within the active video signal by 7.5 IRE when selected
2 If the AUTO dipswitch is set to ON, dipswitches STANDARD 1, STANDARD 2 and STANDARD 3 must be set to OFF.
The machine will auto select between PAL, NTSC, and SECAM only
3 When operating as a bar generator, it is recommended to connect an external CV source (50Hz or 60Hz, according to the
required output standard) in order to stabilize the color sub-carrier frequency
4 For firmware versions up to 2.0, the AGC function cannot be disabled. The AGC dipswitch is only relevant for firmware
versions 2.0 and higher