Performing a Phase Calibration

In the event that there is noise visible on the picture, you should perform a phase
calibration.

To perform a phase calibration:

1. Press the Step-In button to ensure that the SID-VGA is the active input.

The Step-In button lights.

2. Press and hold the Step-In button.

The phase calibration pattern is displayed.

3. Release the Step-In button as soon as the noise disappears.

Technical specifications

Technical specifications of the SID-VGA are shown in

Table 2

.

Table 2: Technical specifications

1

of the SID-VGA UXGA Step-In Commander

INPUTS:

Video: 1 VGA (up to UXGA) on a 15-pin HD (F) connector
Audio: 1 unbalanced stereo audio on a 3.5mm mini jack

OUTPUT:

TP on an RJ-45 Ethernet connector

STEP-IN COMMANDER
DISTANCE:

50m (164ft) up to 1080p @60Hz

POWER CONSUMPTION:

12V DC, 380mA

OPERATING
TEMPERATURE:

0° to +40°C (32° to 104°F)

STORAGE TEMPERATURE:

–40° to +70°C (–40° to 158°F)

HUMIDITY:

10% to 90%, RHL non-condensing

DIMENSIONS:

12cm x 7cm x 2.4cm (4.7" x 2.76" x 0.94”) W, D, H

WEIGHT:

0.3kg (0.66lbs) approx

ACCESSORIES:

Power supply

1 Product details are subject to change without notice


SID-VGA

UXGA Step-In Commander

Installation Instructions

For the latest information on our products and a list of Kramer distributors,

visit our Web site at

www.kramerelectronics.com


P/N:

2900- 000712

Rev:

4

Kramer Electronics, Ltd.

Web site:

www.kramerelectronics.com

E-mail:

[email protected]