beautypg.com

4 your tp-102hd xga/hd line transmitter/da, Your tp-102hd xga/hd line transmitter/da – Kramer Electronics TP-102HD User Manual

Page 6

background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Your TP-102HD XGA/HD Line Transmitter/DA

4

connected to a ground terminal on the units at both ends (use the ground
terminal of the power supply connection if necessary).

For a CAT 5 cable exceeding a distance of 50m, separate power supplies
should be connected to the transmitter and to the receiver simultaneously.

3.2

Shielded Twisted Pair (STP)/Unshielded Twisted Pair (UTP)

We recommend that you use Shielded Twisted Pair (STP) cable. There are
different levels of STP cable available, and we advise you to use the best
quality STP cable that you can afford. Our non-skew-free cable, Kramer
BC-STP is intended for analog signals where skewing is not an issue. For
cases where there is skewing, our UTP skew-free cable, Kramer BC-XTP,
may be used. Bear in mind, though, that we advise using STP cables where
possible, since the compliance to electromagnetic interference was tested
using those cables.

Although Unshielded Twisted Pair (UTP) cable might be preferred for long
range applications, the UTP cable should be installed far away from electric
cables, motors and so on, which are prone to create electrical interference.
However, since the use of UTP cable might cause inconformity to
electromagnetic standards, Kramer does not commit to meeting the standard
with UTP cable.

4

Your TP-102HD XGA/HD Line Transmitter/DA

Figure 1

and

Table 1

define the TP-102HD: