Connecting the VP-108 1:8 XGA / Balanced Stereo Audio DA

9

6.2.2

Setting the MACHINE #

The MACHINE # determines the position of a

VP-108 unit, specifying which

VP-108 unit is being controlled when several VP-108 units connect to a PC

or serial controller. Set the MACHINE # on a

VP-108 unit via DIPS 1, 2 and

3, according to Table 4.
When using a stand-alone

VP-108 unit, set the MACHINE # to 1. When

connecting more than one

VP-108 unit, set the first machine (the Master) that

is closest to the PC, as MACHINE # 1

1

.

Table 4: Machine # Dipswitch Settings

DIPSWITCH

MACHINE #

1

2

3

1

Master

OFF OFF OFF

2

ON OFF OFF

3

OFF ON OFF

4

ON ON OFF

5

OFF OFF ON

6

ON OFF ON

7

OFF ON ON

8

ON ON ON

6.3 Connecting the REMOTE Connector

Connecting the REMOTE terminal block connector pins to a contact closure

switch lets you to disable (and then enable again) output(s) by remote

control

2

. To do so, touch (momentarily) the appropriate REMOTE terminal

block connector pin to the Ground PIN, as Figure 9 illustrates.
For example to disable outputs 1, 2 and 8, touch (momentarily) PIN 1 to the

Ground PIN, and then touch (momentarily) PIN 2 to the Ground PIN, and then

touch (momentarily) PIN 8 to the Ground PIN.
Do not touch (momentarily) more than one PIN to the Ground PIN

simultaneously.

1 Set the dipswitches to OFF
2 An output may also be disabled via RS-232 or RS-485