Installing the VM-50CA on a Rack

6

5 Installing the VM-50CA on a Rack

This section describes what to do before installing on a rack and how to rack

mount.

Before installing on a rack, be sure that the environment is

within the recommended range:

Operating temperature range +5 to +45 Deg. Centigrade

5 to 65% RHL, non-condensing

-20 to +70 Deg. Centigrade
5 to 95% RHL, non-condensing

Operating humidity range
Storage temperature range
Storage humidity range

When installing on a 19" rack, avoid hazards by taking

care that:

It is located within the recommended environmental

conditions, as the operating ambient temperature of a

closed or multi unit rack assembly may exceed the

room ambient temperature.

Attach both ear brackets to the

machine. To do so, remove the

screws from each side of the machine

(3 on each side), and replace those

screws through the ear brackets.

Place the ears of the machine

against the rack rails, and insert the

proper screws (not provided) through

each of the four holes in the rack

ears

.

Note that:

Detachable rack ears can be removed

for desktop use
Always mount the machine in the rack

before you attach any cables or

connect the machine to the power
If you are using a Kramer rack adapter

kit (for a machine that is not 19"), see

the Rack Adapters user manual for

installation instructions (you can

download it at:

http://www.kramerelectronics.com)

In some models, the front panel

may feature built-in rack ears

Once rack mounted, enough air will still flow around the

machine.
The machine is placed straight in the correct horizontal

position.

You do not overload the circuit(s). When connecting

the machine to the supply circuit, overloading the

circuits might have a detrimental effect on overcurrent

protection and supply wiring. Refer to the appropriate

nameplate ratings for information. For example, for

fuse replacement, see the value printed on the product

label.

The machine is earthed (grounded) in a reliable way

and is connected only to an electricity socket with

grounding. Pay particular attention to supply

connections other than direct connections to the

branch circuit (for example, the use of power strips),

and that you use only the power cord that is supplied

with the machine.

CAUTION!!

Before Installing on a Rack

How to Rack Mount