beautypg.com

2 acquiring the default edid, Acquiring the default edid, Connecting a pc to the rs-232 port for programming – Kramer Electronics VM-4HDCPxl User Manual

Page 11

background image

Acquiring the EDID

9

9

While the EDID is being copied, the EDID SELECT and READ buttons

illuminate.

The new EDID is copied when both buttons no longer illuminate.

7.2 Acquiring the Default EDID

To reset to the default EDID, do the following:

1. Turn on the VM-4HDCPxl.
2. Press the EDID SELECT button and set it to the DEFAULT EDID mode.

All the OUTPUT STATUS LEDs flash simultaneously.

3. Press the EDID READ button to copy the default EDID to the input

2

.

While the EDID is being copied, the EDID SELECT and READ buttons

illuminate. The new EDID is copied when both buttons no longer

illuminate.

7.3 Acquiring the Auto-mix EDID from the Connected Outputs

To acquire the Auto-mix EDID:

1. Turn on the VM-4HDCPxl.
2. Connect the desired output display devices.
3. Enter the AUTO-MIX mode as shown in

Figure 3

.

The OUTPUT STATUS LEDs illuminate.

4. Press the READ button to copy the EDID of the selected OUTPUT to the

input

2

.

While the EDID is being copied, the EDID SELECT and READ buttons

illuminate. The new EDID is copied when both buttons no longer

illuminate.

7.4 Connecting a PC to the RS-232 Port for Programming

The RS-232 port is used for service.
This procedure should be performed by qualified personnel only.
To use the RS-232 port for programming

1

1. Turn off the power and disconnect the power cord from the VM-4HDCPxl

and then open the cover.

:

2. Locate the 3-pin jumper on the board

2

1 For firmware upgrade procedure go to our Web site at

http://www.kramerelectronics.com

.

2 Connecting the middle pin and one of the side pins