Chemglass CG-2025 User Manual
Am series lubricated air motors, Peration, Aintenance
Product Use Criteria:
• Normal conditions: Operate at temperatures up to
250 ºF (121ºC).
• Hazardous conditions: Operate at temperatures up to
104ºF (40ºC).
• Protect unit from dirt and moisture.
• Use ONLY compressed air to drive motor.
• Air lines connected to motor should be the same size or
the next size larger than the inlet port for efficient
output and speed control.
• Protect all surrounding items from exhaust air.
• Bearings are grease packed.
• Use Gast #AD220 or a detergent SAE#10 automotive
engine oil for lubricating.
• Motors are to be used in commercial installations only.
• This symbol appears on labels of air motors that
are designed for use in hazardous atmospheres.
These air motors comply with the applicable
standards and specifications and meet the
requirements of the guidelines of the EC directive
94/9EC (ATEX 100a). They are intended to be used in
zones 1 and 2 where explosive atmospheres are likely
to occur.
• Air supply, directional control valve and pressure regulator
should be selected based upon the air consumption
of the motor.
AM SERIES LUBRICATED AIR MOTORS
O
PERATION
& M
AINTENANCE
M
ANUAL
Model 2AM Shown Model 4AM Shown
IMPORTANT: PLEASE READ THIS MANUAL COMPLETELY BEFORE INSTALLING
AND USING THIS MOTOR. SAVE THIS MANUAL FOR FUTURE REFERENCE
AND KEEP IN THE VICINITY OF THE MOTOR.
Thank you for purchasing this Gast product. It is manufactured to the highest standards
using quality materials. This manual includes general safety instructions for operation under normal
conditions and for operation in hazardous conditions. Please follow all recommended maintenance,
operational and safety instructions and you will receive years of trouble free service.
General information
Operating Pressure Limits:
Model
Pressure
1AM
100 PSI / 7 bar
1 UP
80 PSI / 5.6 bar
2 AM
100 PSI / 7 bar
4 AM
100 PSI / 7 bar
6 AM
100 PSI / 7 bar
8 AM
100 PSI / 7 bar
16 AM
100 PSI / 7 bar
Vane Life: Depends upon speed, operating pressure and motor maintenance. In normal operating
conditions inspect vanes after 5,000 to 8,000 hours of operation.
www.gastmfg.com
ISO 9001 & 14001 CERTIFIED