Product Use Criteria:

• Normal conditions: Operate at temperatures up to

250 ºF (121ºC).

• Hazardous conditions: Operate at temperatures up to

104ºF (40ºC).

• Protect unit from dirt and moisture.
• Use ONLY compressed air to drive motor.
• Air lines connected to motor should be the same size or

the next size larger than the inlet port for efficient
output and speed control.

• Protect all surrounding items from exhaust air.
• Bearings are grease packed.
• Use Gast #AD220 or a detergent SAE#10 automotive

engine oil for lubricating.

• Motors are to be used in commercial installations only.
This symbol appears on labels of air motors that

are designed for use in hazardous atmospheres.

These air motors comply with the applicable
standards and specifications and meet the
requirements of the guidelines of the EC directive
94/9EC (ATEX 100a). They are intended to be used in
zones 1 and 2 where explosive atmospheres are likely
to occur.

• Air supply, directional control valve and pressure regulator

should be selected based upon the air consumption
of the motor.

AM SERIES LUBRICATED AIR MOTORS

O

PERATION

& M

AINTENANCE

M

ANUAL

Model 2AM Shown Model 4AM Shown

IMPORTANT: PLEASE READ THIS MANUAL COMPLETELY BEFORE INSTALLING

AND USING THIS MOTOR. SAVE THIS MANUAL FOR FUTURE REFERENCE

AND KEEP IN THE VICINITY OF THE MOTOR.

Thank you for purchasing this Gast product. It is manufactured to the highest standards

using quality materials. This manual includes general safety instructions for operation under normal

conditions and for operation in hazardous conditions. Please follow all recommended maintenance,

operational and safety instructions and you will receive years of trouble free service.

General information

Operating Pressure Limits:

Model

Pressure

1AM

100 PSI / 7 bar

1 UP

80 PSI / 5.6 bar

2 AM

100 PSI / 7 bar

4 AM

100 PSI / 7 bar

6 AM

100 PSI / 7 bar

8 AM

100 PSI / 7 bar

16 AM

100 PSI / 7 bar

Vane Life: Depends upon speed, operating pressure and motor maintenance. In normal operating

conditions inspect vanes after 5,000 to 8,000 hours of operation.

www.gastmfg.com

ISO 9001 & 14001 CERTIFIED

®Registered Trademark/™Trademark of Gast Manufacturing Inc., Copyright © 2003 Gast Manufacturing Inc. All Rights Reserved.

PART NO. 45-200 D170PL

Model 6AM Shown

Model 16AM Shown