Electrical specifications – RMS Technologies IMDE17 INTEGRATED MOTOR + DRIVER + ENCODER User Manual
Page 6

RMS Technologies
Page 6
Version 1.04
IMD17/IMDE17
10/1/2007
2. ELECTRICAL SPECIFICATIONS
Power Supply Requirements
Voltage
+12 VDC to +24 VDC
Driver
Peak Current:
0.35 to 2.0 Amps OR 0.25 to 1.4 Amps
Motor Specifications
NEMA Size 17
Holding Torque (default – 23% holding current):
IMD17-S05
34.5
oz-in
IMD17-M04
48.5
oz-in
IMD17-L04
63.9
oz-in
Holding Torque (special* – 100% holding current):
IMD17-S05
45
oz-in
IMD17-M04
63
oz-in
IMD17-L04
83
oz-in
Steps per Revolution (1.8° Motor)
200, 400, 800, 1600
*NOTE: The IMD17/IMDE17 by default use 23% of the run current as it’s hold current. If
your require more holding torque, the other option is to use 100% of the run current as
your holding current, which must be special ordered.