Pag e 7 – Australian Monitor AMISCL2 User Manual
Page 7

A M I S C L 2 I N S TA L L AT I O N & O P E R AT I O N M A N UA L
PAG E 7
S P E C I F I C AT I O N S
AU D I O I N P U T
Type
RF-filtered, Servo-balanced input stage
Impedance
60K
Ω
balanced
Nominal Operating Level
-10dBu to +4dBu
Maximum Input Level
+21dBu balanced and unbalanced
CMR @ 1kHz
>40dB
D E T E C TO R I N P U T
Type
DC de-coupled, unbalanced input
Impedance
>20K
Ω
Maximum Input Level
+21dBu
AU D I O O U T P U T
Type
Electronically buffered output stage
Impedance
<40
Ω
Maximum Input Level
+21dBu
Bandwidth
5Hz to 50kHz, +0, -1dB
THD @ +4dBu
0.05% typ.
THD @ +20dBu
0.1% typ.
IMD (SMPTE) @ +10dBu
0.01% typ.
Noise & Hum, unity gain
>93dBu
Noise & Hum, fully off
>97dBu
Crosstalk @ 20kHz
>85dBu
CMR @ 1kHz
>60dBu
C O M P R E S S O R S E C T I O N
Type
IKC (Interactive Knee Control) Compressor
Threshold
Variable (-40 to +20dBu)
Ratio
Variable (1:1 to LIM.)
Attack
Variable (0.1 to 200 msec./20dB)
Release
Variable (-20 to +20dB)
G AT E S E C T I O N
Type
IRC (Interactive Ratio Control) Expander/Gate
Threshold
Variable (Off to +10dBu)
DY N A M I C E N H A N C E R S E C T I O N
Type
Dynamically Controlled Frequency Correction
Process
Variable (Off to 6)
F U N C T I O N S W I T C H E S
In/Out
Bypass switch
Auto
Programme-dependent attack and release times
I N D I C ATO R S
CLOSE LED
LED indicates onset of the Expander/Gate
8 element GAIN REDUCTION meter
1/2/4/6/10/15/20/30dB
P OW E R S U P P LY
Mains Voltages
100-120/200-240 VAC 50-60Hz
Power Consumption
9 Watts
Fuse
320mA (100-120V); 160mA (200-240V) slow-blow
Mains Connection
Standard IEC receptacle
P H Y S I C A L
Dimensions H x W x D
13/4” (44.5mm) x 19” (482.6mm) x 8.5” (217mm)
Net Weight
3kg
Shipping Weight
4.3kg
As a result of these efforts, modifications may be made from time to time to existing products without prior notice.
Specifications and appearance may differ from those listed or shown.