Using the gui – Australian Monitor AMD200 User Manual
Page 11

Priority:
The Priority window allows you to adjust which inputs have priority over others.
There are four levels of priority in the AMD Series.
Level 0 – No Priority
Level 1 – Low Priority
Level 2 – Medium Priority
Level 3 – High Priority
Level 4 – Highest Priority
When two inputs share the same level of priority they will both stay active when
the lower priority channels mute.
The threshold at which the priority will become active is adjusted via the control
at the top of the page.
All inputs will trigger from the same audio level set from the priority threshold control.
Bell and Chimes have selectable priority and can sit on any of the 5 levels.
Evac and Alert are fi xed to the highest level of priority.
BGM sources are fi xed to the lowest level of priority.
Tones:
The tone generator window allows you to adjust the volume of the tones
present in the AMD Series. The following tones are available:
Bell (Pre Master Level)
Chimes (Pre Master Level)
Alert (Post Master Level)
Evac (Post Master Level)
All tones volumes are by default set to -12 db.
PAGE 11
AMD100/200 INSTALLATION AND OPERATION MANUAL
USING THE GUI