Side view of cabinet, Nstallation – Glastender LP108 User Manual
Page 5
4
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
(Cleaning Instructions continued from page 3)
PROCEDURE:
1. A non-chlorine based cleaner or mild detergent and warm water
applied with a soft cloth or sponge to all contact surfaces.
2. Immediately rinse off cleaning agent(s), using clean warm water,
clean soft cloth or sponge.
3. Dry with a soft clean cloth, removing standing water as soon as
possible.
4. Condenser filter - remove small louvered covers only. Do NOT
remove compressor cover panel as thermostat control probe wire
will become disconnected and cause operation failure not covered
by factory warranty (see page 2).
NOTES:
1. Never use hydrochloric acid, wire brushes, steel wool, scrapers, or
chlorine based cleaners on stainless steel surfaces, since they will
break down the passivity layer and allow corrosion to occur.
2. On stainless steel surfaces, you may use a soft bristle brush or Scotch-Brite
®
pad for more stubborn stains. Always
scrub with the direction of the grain. Follow with a thorough cleaning as described above.
3. Deposits from food preparation must be properly removed. Even hard water deposits will rust stainless steel, if not
removed.
4. Repeated cleaning may dry up black-vinyl-clad steel (exterior) surfaces of the cooler. Armor All
®
or similar product
can bring back the shine. Apply the product to a cloth and then rub into the surface, rather than spraying it directly onto
the black-vinyl-clad surface.
5. The cooler door gaskets are most often overlooked when cleaning. Failure to clean them regularly will lead to prema-
ture failure, since alcohol and moisture build-up breaks down the gasket material.
S
ealiNg
v
ertiCal
d
oor
C
ooler
to
f
loor
To comply with NSF & health codes, the cooler base must be sealed to the floor using NSF listed sealant. Place a bead
of sealant along outer edges of the base and remove excess with disposable towel. The floor sealing procedure does not
apply to models that include legs or casters.
i
NStallatioN
COOLER DOOR
COOLER CABINET
1" BASE
BEAD SEALANT
FLOOR
MAGNETIC GASKET
Side View of Cabinet
Cleaning condenser filter:
Do NOT remove
compressor panel
Remove small louvered
covers only