Table 3
Impeller Clearances
Cold Temperature Clearances for Various Service Temperatures, inches (mm)
Service Temperature
3196 and HT3196
LF3196
STX
MTX/LTX
XLTX/X17
STX MTX/LTX
inches
mm
inches
mm
inches
mm
inches
mm
-20 to 150°F (-29 to 66°C)
0.005
0.13
0.008
0.20
0.015
0.38
0.015
0.38
Up to 175°F (79°C)
0.005
0.13
0.008
0.20
0.015
0.38
0.015
0.38
Up to 200°F (93°C)
0.005
0.13
0.008
0.20
0.015
0.38
0.015
0.38
Up to 250°F (121°C)
0.006
0.16
0.009
0.23
0.016
0.41
0.016
0.41
Up to 300°F (149°C)
0.007
0.19
0.010
0.26
0.017
0.44
0.017
0.44
Up to 350°F (177°C)
0.009
0.22
0.012
0.29
0.019
0.47
0.019
0.47
Up to 400°F (204°C)
0.010
0.25
0.013
0.32
0.020
0.50
0.020
0.50
Up to 450°F (232°C)
0.011
0.28
0.014
0.35
0.021
0.53
0.021
0.53
Up to 500°F (260°C)
0.012
0.30
0.015
0.38
0.022
0.56
0.022
0.56
Up to 550°F (288°C)
0.013
0.33
0.016
0.41
0.023
0.59
0.023
0.59
Up to 600°F (316°C)
0.014
0.36
0.017
0.44
0.024
0.62
0.024
0.62
Up to 650°F (343°C)
0.016
0.39
0.019
0.47
0.026
0.65
0.026
0.65
Up to 700°F (371°C)
0.017
0.42
0.020
0.50
0.027
0.68
0.027
0.68
Table 3, cont’d
Impeller Clearances
Cold Temperature Clearances for Various Service Temperatures, inches (mm)
Service Temperature
CV 3196
1
3796
NM 3196
3198
STX MTX/LTX XLTX
STX MTX/LTX
STX
MTX/LTX
STX MTX/LTX
-20 to 150°F (-29 to 66°C)
0.06
1.52
0.015
0.38
0.005
0.13
0.008
0.20
0.015
0.38
Up to 175°F (79°C)
0.06
1.52
0.015
0.38
0.005
0.13
0.008
0.20
0.020
0.51
Up to 200°F (93°C)
0.06
1.52
0.015
0.38
0.005
0.13
0.008
0.20
0.024
0.61
Up to 250°F (121°C)
0.06
1.52
0.016
0.41
0.032
0.81
Up to 300°F (149°C)
0.06
1.52
0.017
0.44
0.040
1.02
Up to 350°F (177°C)
0.06
1.52
0.019
0.47
Up to 400°F (204°C)
0.06
1.52
0.020
0.50
Up to 450°F (232°C)
0.021
0.53
Up to 500°F (260°C)
0.022
0.56
Up to 550°F (288°C)
Up to 600°F (316°C)
Up to 650°F (343°C)
Up to 700°F (371°C)
Out of pump temperature range =
1