D. indicating switch option installation, B. connect blue lead to common output – APTech AZ4571 User Manual
Page 3

Operation Manual
Pneumatic Diaphragm Valves (NC)
D. Indicating Switch Option Installation
1. IS option for AK/AP/AZ3000, AP3113, AP3130, or AK/AP/AZ3200:
a.
Review the following specifications to verify the switch is appropriate for the installation.
Switch model
OKI Sensor ORT551
Switch type
SPDT
Operating temperature
-40 to 80 C
Supply voltage
30 VDC max.
Power
3 VA max.
Switching current
0.2 A max.
Carrying current
0.5 A max.
Life expectancy
Up to 5,000,000 cycles at 1.2 VA
Connectors
Stranded 24 AWG wire (blue, black, and
brown leads), 10 ft (3 m) long
b.
Connect blue lead to common output.
c.
Connect brown lead to normally closed input (the circuit will be closed when valve is
closed).
d.
Connect black lead to normally open input (the circuit will be closed when valve is open).
2. ISO and ISC option for AK/AP/AZ3550, AK/AP/AZ4550, or AP3700:
a.
Review the following specifications to verify the switch is appropriate for the installation.
ISO switch model
Alcoswitch MSPM101C104
ISC switch model
Alcoswitch MSPM101B104
Switch type
SPST
Operating temperature
-10 to 80 C
Supply voltage
50 VDC max.
Supply current
100 mA max.
Power
1.0 VA optimum
Initial contact resistance
100 milliohm max.
Life expectancy
up to 5,000,000 cycles at 0.1 VA
Connectors
Lug terminals – can be soldered or will accept
.110 quick disconnect receptacles
b.
Connect common input to one lug terminal (solder wire or use .110 quick disconnect
receptacle).
c.
Connect signal input to other lug terminal (solder wire or use .110 quick disconnect
receptacle). For ISO option, the circuit will be closed when the valve is open. For ISC, the
circuit will be closed when the valve is closed.