APTech KT12 User Manual
Page 9

Operation Manual
Piston Sensed Pressure Regulators
Figure 4. Pneumatically actuated KT10 delivery pressure vs. actuation control pressure.
* Note: KT10R not available on welded body KT10’s.
______________________________________________________________________________________________________________________
Figure 5. Pneumatically actuated KT12 delivery pressure vs. actuation control pressure.
0
500
1000
1500
2000
2500
3000
3500
0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
Actuation Control Pressure (psig)
D
el
iv
ery
P
re
ss
u
re (
p
si
g
)
0
34
69
103
138
172
207
241
0.00
0.69
1.38
2.07
2.76
3.45
4.14
4.83
5.52
Actuation Control Pressure (bar)
D
el
iv
ery
P
re
ss
u
e (
b
a
r)
KT12L
KT12J
KT12G
0
1000
2000
3000
4000
5000
6000
7000
8000
9000
10000
0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
Actuation Control Pressure (psig)
D
el
iv
ery
P
res
su
re (
p
si
g
)
0
69
138
207
276
345
414
483
552
621
690
0.00
0.69
1.38
2.07
2.76
3.45
4.14
4.83
5.52
Actuation Control Pressure (bar)
D
el
iv
ery
P
res
su
e (
b
a
r)
KT10R *
KT10N
KT10J
KT10H
Page 9 of 9
Manual 15000011 Rev. 5