beautypg.com

Troubleshooting – Minka Group F574-WH User Manual

Page 20

background image

11

TROUBLESHOOTING

SYMPTOM
Fans/Light Turn On
and Off Unexpectedly

SOLUTION
This is caused by

interference, change the
code frequency from the
transmitter, and follow
the instructions from
Section 5 again to
operate your transmitter
and fan.

SYMPTOM

Fan Sounds Noisy

SOLUTION

Allow a 24-hour "break in" period.

Most noises associated with a

new fan will go away during this

time.

Make sure the screws that attach

the fan blade holder to the motor

hub is tight.

Make sure outlet box is secured

to building structure, if

necessary use the wood screws

provided to further secure

outlet box to joist.

Make sure hanger bracket is

secure to the outlet box, screws

are tight.

SYMPTOM

Fan will not start
SOLUTION

Check to make sure the wall switch is

turned on.

Check circuit fuses or breakers.

Caution! Make sure the power is turned

off before performing the following steps.

Remove canopy and check wire

connections.

Check wall control transmitter connections

(if applicable).

Note: Fan must be installed at a maximum

distance of 40 feet from the transmitting

unit for proper signal transmission

between the transmitting unit and the

fan's receiving unit.

SYMPTOM

Fan Wobble

SOLUTION

NOTE: All blade sets are grouped by

weight. Because wood and plastic blades

vary in density, the fan may wobble

even though blades are matched.

Make sure outlet box is secured to

building structure, if necessary use the

wood screws provided to further secure

outlet box to joist.

Make sure hanger bracket is secure to

the outlet box, screws are tight.

Use the balancing kit provided if the

wobble is excessive. (follow instructions

included with balancing kit.)

This manual is related to the following products: