Meteor ProMover 1200 CYM User Manual
Page 6

9
PRISM TOTATION
10
PRISM STREAM
11
FIXATION GOBO
12
GOBO STREAM
13
GOBO ROTATION
14
CYAN
15
MAGENTA
16
YELLOW
17
GRADUAL CHANGE
18
PAN 16BIT
19
TILT 16BIT
20
GOBO FINE
Select the options by setting the microswitches as indicated:
Option
Function
1
ON
Linear movement of the color wheel
OFF
Stepped movement of the color wheel
2
ON
Linear moving of the fixed gobo disc
OFF
Stepped movement of the fixed gobo wheel
3
ON
Lamp control enabled
OFF
Auto light off after 5 min. of blackout disenabled
4
ON
PAN Fine and TILT Fine control enable
OFF
PAN Fine and TOLT Fine control disable
5
-
PAN direction change
6
-
TILT direction change
7
ON
Gobo Fine control enable
OFF
Gobo Fine control disable
8
ON
CMY color mixing system selected
OFF
RGB color-mixing system selected
9
-
NOT USED
10
ON
Display orientation for ceiling installation
OFF
Display orientation for floor installation
11
-
TEST
12
-
If ON, there is Low Voltage Supply on output at DMX
signal input connector pin
TECHNICAL INFORMATION
Power supplies available
*Version with electronic ballast (with and without PFC):
-200-240V 50/60Hz
-100-120V 50/60Hz
*Version with electromagnetic ballast:
-230V 50Hz
-240V 50Hz
-20BV 60Hz
-200V 50Hz
-200V 60Hz
The projector is designed to operate at the mains frequency and voltage given on the
electrical data label of the appliance.