beautypg.com

5 hardware monitor, Smart fan control [disabled, Cpu fan mode [pwm – Asus L1N64-SLI WS User Manual

Page 92

background image

-2

Chapter : BIOS setup

4.5.5

Hardware Monitor

Hardware Monitor
CPU1 Temperature

[60ºC/140ºF]

CPU2 Temperature

[60ºC/140ºF]

MB Temperature

[46ºC/114.5ºF]

Smart Fan Control

[Disabled]

CPU Fan Mode

[PWM]

CPU Fan1 Speed

[2564RPM]

CPU Fan2 Speed

[4354RPM]

CHA Fan1 Speed

[N/A]

CHA Fan2 Speed

[N/A]

SPS Fan Speed

[4655RPM]

HP Fan3 Speed

VCORE1 Voltage

[ 1.440V]

VCORE2 Voltage

[ 1.440V]

3.3V Voltage

[ 2.992V]

5V Voltage

[ 4.889V]

12V Voltage

[10.579V]

CPU1/CPU2 Temperature [xxxºC/xxxºF]

MB Temperature [xxxºC/xxxºF]

The onboard hardware monitor automatically detects and displays the motherboard

and CPU temperatures. Select [Disabled] if you do not wish to display the detected

temperatures.

Smart Fan Control [Disabled]

Allows you to enable or disable the smart fan feature that smartly adjusts the fan

speeds for more efficient system operation. Configuration options: [Disabled]

[Enabled]

CPU Fan Mode [PWM]

Allows you to select the type of CPU fan cable connected to the CPU fan

connector. Set to [PWM] when using a 4-pin CPU fan cable. Set to [DC] when

using a 3-pin CPU fan cable. Configuration options: [PWM] [DC]

Some CPU fans with a 4-pin cable do not comply with Intel

®

’s PWM fan

specification. When using this type of CPU fan, you can not reduce the CPU fan

speed even if you set the CPU Q-Fan Mode to [PWM].

CPU Fan1/Fan2 Speed (RPM) [xxxxRPM] or [N/A] or [Ignored]

The onboard hardware monitor automatically detects and displays the CPU

fan speed in rotations per minute (RPM). If the fan is not connected to the

motherboard, the field shows N/A. Select [Ignore] from the item options to disable

CPU fan speed monitoring.

CPU Temperature

This manual is related to the following products: