beautypg.com

I/o c, Dmx pathfinder lr installation & assembly, Able – Pathway MR Installers Guide User Manual

Page 9: Onnection, Dmx pathfinder mr

background image

DMXPathfinder LR

Installation & Assembly

8


I/O C

ABLE

C

ONNECTION

Strip back about 3 inches (8cm) of cable jacket and braid shield from each

input or output cable. Apply a 2.5" (6.5cm) piece of 1/16" heat shrink to the
drain wire and a 1" (2.5cm) piece of 3/8" heat shrink over the exposed braid
ends where each cable was stripped. These precautions are to ensure that
cable shields cannot contact each other or equipment ground.


Strip about 1/2" of insulation from the four signal wires in each cable. Bend

over 1/4" of the exposed conductors on all five wires and connect them to the
terminal block. Note that each five-position terminal block is numbered 1 thru
5 on the termination board. This corresponds to the pin numbering on XLR
5-pin connectors, that is:

INTER-MODULE BUS

PORT A

PORT B

PORT C

PORT D

PORT E

DMX INPUTS

PORT F

PORT G

PORT H

OUTPUT 5-8

OUTPUT 5-8

OUTPUT 1-4

OUTPUT 1-4

J2

J2

J1

J1

J4

J4

J3

J3

J6

J6

J5

J5

J10

J10

J12

J12

J9

J9

J9

J11

J11

J11

J13

J8

J8

J7

J7

OUTPUT 13-16

OUTPUT 13-16

OUTPUT 9-12

OUTPUT 9-12

OUTPUT 21-24

OUTPUT 21-24

OUTPUT 17-20

OUTPUT 17-20

OUTPUT 29-32

OUTPUT 29-32

OUTPUT 25-28

OUTPUT 25-28

INTER-MODULE BUS

INTER-MODULE BUS

INTER-MODULE BUS

INTER-MODULE BUS

INTER-MODULE BUS

INTER-MODULE BUS

PC-COM

CPS
TxD

CABLE B THRU

CABLE B THRU

CABLE B THRU

CABLE B IN

CABLE B IN

CABLE B IN

CABLE A THRU

CABLE A THRU

CABLE A THRU

CABLE A IN

CABLE A IN

CABLE A IN

RxD
COM
TxD+
TxD-
RxD+
RxD-

J13

PC-COM

CPS
TxD
RxD
COM
TxD+
TxD-
RxD+
RxD-

J13

PC-COM

CPS
TxD
RxD
COM
TxD+
TxD-
RxD+
RxD-

POWER IN

POWER IN

POWER IN

POWER IN

100-240V

100-240V 50/60Hz

100-240V

100-240V

50/60Hz

50/60Hz

50/60Hz

1

1

1

1

1

1

1

1

2

2

2

2

2

2

2

2

3

3

3

3

3

3

3

3

4

4

4

4

4

4

4

4

5

5

5

5

5

5

5

5

TB32

TB24

TB16

TB8

TB31

TB23

TB15

TB7

TB30

TB22

TB14

TB6

TB29

TB21

TB13

TB5

TB28

TB20

TB12

TB4

TB27

TB19

TB11

TB3

TB26

TB18

TB10

TB2

TB25

TB17

TB9

TB1

Input Module
(inputs 1 - 8)

Output Module #1
(outputs 1 - 32)

Output Module #2
(outputs 33 - 64)

Output Module #3
(outputs 65 - 96)

32-WAY OUTPUT MODULE

DMX Pathfinder MR

MODEL NUMBER

SERIAL NUMBER

MADE IN CANADA

100-250 VAC
50/ 60Hz 1.0A

32-WAY OUTPUT MODULE

DMX Pathfinder MR

MODEL NUMBER

SERIAL NUMBER

MADE IN CANADA

100-250 VAC
50/ 60Hz 1.0A

32-WAY OUTPUT MODULE

DMX Pathfinder MR

MODEL NUMBER

SERIAL NUMBER

MADE IN CANADA

100-240 VAC
50/ 60Hz 1.0A