Technical data – Aga Ranges 6-4 Series User Manual
Page 4

HOTPLATE
NATURAL GAS
L.H.F.
R.H.F.
R.H.R.
L.H.R.
CENTRE
CENTRE
WOK
FRONT
REAR
BURNER TYPE
ULTRA-RAPID RAPID
RAPID
SEMI-RAPID SEMI-RAPID ULTRA-RAPID
MAXIMUM HEAT
4.5 kW
3.22 kW
3.22 kW
1.91 kW
1.91 kW
5.1 kW
INPUT
BTU’s/hr
15,350
11,000
11,000
6,500
6,500
17,400
INJECTOR MARKING
MAIN
80Hi
155
155
118
118
200
SECONDARY
2 x 1.30
-
-
-
-
-
PRESSURE POINT POSITION: REAR RH SIDE OF HOTPLATE
PRESSURE SETTING:
4” W.G.
BURNER IGNITION: H.T. SPARK
PROPANE
L.H.F.
R.H.F.
R.H.R.
L.H.R.
CENTRE
CENTRE
WOK
FRONT
REAR
BURNER TYPE
ULTRA-RAPID RAPID
RAPID
SEMI-RAPID SEMI-RAPID ULTRA-RAPID
MAXIMUM HEAT
4.2 kW
3.0 kW
3.0 kW
1.75 kW
1.75 kW
4.5 kW
INPUT
BTU’s/hr
14,330
10,250
10,250
6000
6000
15,350
INJECTOR MARKING
MAIN
46
85
85
65
65
110
SECONDARY
2 x 66
-
-
-
-
-
PRESSURE POINT POSITION: REAR RH SIDE OF HOTPLATE
PRESSURE SETTING: 10” W.G.
BURNER IGNITION: H.T. SPARK
ELECTRIC GRILL AND OVENS
WEIGHT OF APPLIANCE: 220 kg
TOP OVEN POWER RATING - 1.45 kW
BROILER ELEMENT - POWER RATING 2.45 kW
SLOW COOKING OVEN - POWER RATING 1.0 kW
LOWER OVEN (FAN) - 2.2 kW
240 VOLT 60 Hz SINGLE PHASE
The data plaque is located on a pull out plate - lower front of appliance (See Fig. 10, Page 22).
TYPICAL SECTION VIEW OF FLAMES:
TECHNICAL DATA
4
15/16”
9/16”
7/8”
1/2”
3/4”
9/16”
LHF HOTPLATE BURNER
CR HOTPLATE BURNER
RHF & RHR HOTPLATE
BURNER