Machine Components
The TP18SX-HP is made of the following components:
Machine body (Solution and recovery tank)
Solution and vacuum hoses, used to connect the machine body to the carpet wand.
Carpet wand
Pre-spray hose and gun, for carpet pre-spraying
The machine body contains:
The solution tank, containing water used for cleaning
The recovery tank, used to recover the dirty water
The solution pump and the vacuum motors, situated inside the lower tank,
The control panel for the pump and the motors,
The lower control panel, used to switch from cleaning mode to rinsing mode and to
adjust the pump pressure.
Preparation the Machine
To prepare the machine for use, do the following:
1. Connect the pre-spray gun to the pre-spray hose and the pre-spray hose to the quick
disconnect coupling located on the lower panel.
2. Connect the vacuum hose to the rear of the recovery tank.
3. Connect the carpet wand to the solution and vacuum hose.
4. Add water into the solution tank. Put only water, without chemical. Use clean buckets
only.
5. Place the chemical bottle into the holder located on top of the lower control panel.
Check that the chemical bottle is properly connected to the chemical input on the lower
control panel and that it is not empty.
6. Connect the plug of the machine to a properly grounded electrical socket. Please see
the “Electrical Safety” paragraph on page 2 before carrying out this operation.