頁面 13 – MIPRO ACT-80T Wideband Digital Miniature Bodypack Transmitter User Manual
Page 13

ERR: Error Code
If the LCD displays “ERR” after turning on the
power, it indicates the operation is not correct. The
error codes are as follows:
ROM-ER → Transmitter does not have the initial
data so the microphone is completely
dead and cannot be programmed.
ERROR1 →Failure on RF circuitry, frequency
cannot be programmed.
NO----OR3 →Frequency to be programmed into
the transmitter exceeds the highest
frequency of the designated
frequency band of the transmitter.
NO----OR4 →Frequency to be programmed into
the transmitter exceeds the lowest
frequency of the designated
frequency band of the transmitter.
**Note:
NO----OR3 and NO----OR4 will not change the
transmitter's original frequency and the
transmitter will still operate normally with the
error message on display. To remove the error
message from the display panel, please switch
off the transmitter and switch it on again.
Digital Bodypack Transmitter
Digital Bodypack Transmitter
22
21
100%
80%
60%
40%
20%
10%
Battery Status
Indicates the power remaining in the transmitter
battery. When the battery has less than 10% power
remaining it must be replaced or recharged. If an
under voltage condition continues, the LCD will
show “OFF...” and the system will shut down to
prevent being overly discharged.
OFF...
“OFF...” : Power Off
1. Press and hold power button for 2 seconds to
power on & off.
2. When the power switch is turned off, the LCD
will show “OFF…” (for Power Off) first and then
the system will shut down and no further
messages will be displayed.