beautypg.com

3 technical data, 3technical data – Beijer Electronics iX Panel T60 EN User Manual

Page 10

background image

Technical Data

3

Technical Data

Parameter

iX Panel T60

Front panel, W x H x D

202 x 152 x 6 mm

Mounting depth

57 mm (157 mm including clearance)

Front panel seal

IP 66

Rear panel seal

IP 20

Keyboard
material/Front
panel

Touch screen: Polyester on glass, 1 million finger touch
operations. Overlay: Autotex F157 or F207*.

Reverse side
material

Powder-coated aluminum

Weight

0.9 kg

Serial port
RS422/RS485

25-pin D-sub contact, chassis-mounted female with
standard locking screws 4-40 UNC

Serial port RS232C

9-pin D-sub contact, male with standard locking screws 4-40
UNC

Ethernet

Shielded RJ 45

USB

Host type A (USB 1.1), max output current 500 mA

Real time clock

±20 PPM + error because of ambient temperature and supply
voltage. Total maximum error: 1 min/month at 25 °C.
Temperature coefficient: -0.034±0.006 ppm/°C

2

Real time clock
battery

CR2450 (UL and cUL: Sanyo or Panasonic)
Minimum lifetime: 3 years

Power consumption
at rated voltage

Normal: 0.2 A
Maximum: 0.4 A

Display

TFT-LCD.320 x 240 pixels, 64K colors.
LED backlight lifetime at the ambient temperature of
+25 °C: >20,000 h.

Active area of
display, W x H

115.2 x 86.4 mm

Fuse

Internal DC fuse, 2.0 AT, 5 x 20 mm

Power supply

+24 V DC (20 - 30 V DC). Power supply connector.
CE: The power supply must conform with the requirements
according to IEC 60950 and IEC 61558-2-4.
UL and cUL: The power supply must conform with the
requirements for class II power supplies.

Ambient
temperature

Vertical installation: 0 ° to +50 °C
Horizontal installation: 0 ° to +40 °C

Storage temperature

-20 ° to +70 °C

Relative humidity

5 - 85 % non-condensed

Approvals and
certifications

Information is available on the web site

www.beijerelectronics.com

* See section

Chemical Resistance

for more information.

Beijer Electronics, MAEN991A

10