6 Troubleshooting
6.1 General
Troubleshooting
The table below lists general troubleshooting that may arise with your gateway.
Table 6-1: General Troubleshooting
Problem
Possible Cause
Solution
Ready
LED is lit red
Hardware component
failure.
Contact AudioCodes' Customer Support
representative.
Ethernet cable
disconnected.
Ensure that the Ethernet cable is plugged firmly into
the Ethernet port.
Unable to access
Embedded Web Server
No IP connectivity due to
incorrect IP addressing
scheme.
Ensure that the IP address, subnet mask, and default
gateway are correctly configured by connecting
directly to the gateway using CLI (serial) or HTTP
(local Ethernet connection), as described in Section
Configuration settings
have been lost
Hardware failure.
Restore the gateway's configuration settings by
uploading the backup ini file (refer to Section
on page
Unable to access
Embedded Web Server
due to forgotten/lost
login password
--
Restore the gateway's default configuration settings
(refer to Section
on page
Note:
Default username and password is 'Admin'.
6.2
Restoring Parameters to Factory Default Settings
You can use the hardware Reset button to restore the gateway's configuration parameters to their
factory defaults (default IP addresses are listed in
). Therefore, after you have restored
factory defaults, you must load your previously backed-up ini file, or the ini file downloaded from
AudioCodes' Web site to set the gateway's configuration parameters to their correct values.
¾
To restore factory default settings, take these 3 steps:
1.
With a paper clip or any other similar pointed object, press and hold down the Reset button
(located on the rear panel for MP-11x and front panel for MP-124) for about six seconds; the
gateway is restored to its factory settings.
2.
Assign the gateway an IP address (refer to Section
3.
Load your previously backed-up ini file, or the ini file downloaded from the Web site. To load
the ini file via the Embedded Web Server, refer to Section
on page
6.3
Debugging using a Syslog Server
The Syslog client, embedded in the gateway, sends error reports and events generated by the
gateway to a Syslog server application, using IP/UDP protocol. The Syslog server can be
AudioCodes proprietary Syslog server (ACSyslog) or any third-party, Syslog server such as Kiwi
Enterprise