beautypg.com

Tubing assembly installation and lubrication – Pulsafeeder Chem-Tech Series XP EN User Manual

Page 12

background image

REV. L PN J63031

- 12-

6.2 Tubing Assembly Installation and Lubrication

WARNING:

When using the pump to load tubing the rocker switch must be in

the Off (

“O”) position to prevent accidental motor starting. Caution must be used

to keep fingers away from rotating parts.











Figure 8: Pump Head w/ Rotor Assembly Removed

NOTE: Lubrication of rotor assembly should be performed at least once a year
(residential service). Clean front and rear rotor bearings and surfaces with a
clean shop cloth (See head assembly illustration at the end of this manual).
Lubricate with a PTFE thickened, medium viscosity, synthetic grease intended for
plastic parts. Ref. Grease Kit (P/N J30257)

– see Figure 8.


1. Reinstall the rotor assembly by aligning the cross in the rotor to the drive shaft
cross and fully insert into pump head.

2. Use the 100% button and align the rotor assembly as shown in Figure 9a.

Figure 9a: Rotor Alignment at Start of Tube Installation

Note position of
tube and rotor’s
cut-away guide
slot.

Lube all roller (3)
and bearing
surfaces (2)

P/N NC82XX3LP1-XXXXX

ROLLER ASSEMBLY