Pump does not work, Overload trips, Intermittent running – Power Soak MX-220-T Owner's Manual User Manual
Page 19
18
Authorized Service Agency Section
Pump does not work
Look For
Correction
1 No water in sink
Fill sink with water
2 LIQUID LEVEL SENSOR dirty
Clean LIQUID LEVEL SENSOR
3 No incoming power to unit
Reset customer’s breaker in breaker control panel
4 Blown fuses
Replace blown fuse – Refer to wiring diagram for correct fuses
5 Loose wires
Tighten wires
6 LIQUID LEVEL CONTROL setting is too low
See page 20
7 Defective LIQUID LEVEL CONTROL or SOCKET Check and replace as necessary
8 Tripped OVERLOAD
Push red RESET bar on OVERLOAD
9 Defective START or STOP switch
Check and replace as necessary
10 TIMER settings incorrect
Check – See page 21
11 Defective TIMER
Check and replace as necessary
12 Defective CONTACTOR/OVERLOAD
Check and replace as necessary
13 Defective PUMP MOTOR
Check and replace as necessary
Overload trips
Look For
Correction
1 Low voltage to unit
Check with Volt meter while running
2 Improper Setting on Overload
Set on “10”
3 Debris in PUMP intake
Clean
4 Debris in IMPELLER
Remove PUMP and clean
5 Defective CONTACTOR
Check and replace as necessary
6 Defective OVERLOAD
Check and replace as necessary
7 Defective PUMP MOTOR
If amp draw is greater than 10% of motor rating and all of above check
out, then replace MOTOR
Intermittent running
Look For
Correction
1 See 2, 5, 6, 7, 9, 10, 11 under
Pump does not work
2 Overload Tripping and Resetting
See “Overload Trips”
3 Sink not filled to “Water Line”
Make sure sink is filled to “Water Line”. Soap foam does not
count.