Troubleshooting – Nor-Lake AdvantEDGE Pizza Prep Tables User Manual
Page 3

08/13 Rev. B 146574
3
TROUBLESHOOTING
Problem
Remedy
Compressor will
not start
· Check the power cord and make sure it is plugged in.
· Check the temperature controller. If it is in the “OFF”
position, turn it clockwise to set a desired temperature.
Poor performance
· Move the unit from direct sunlight.
· Move the unit away from heating devices.
· Install the unit in a well ventilated place,
with at least 7 inches of clearance on all sides.
· Clean the condenser if heavy dust is collected.
· Clear contents from blocking the air duct.
· Check the temperature controller for incorrect setting.
· Check the refrigerant level, it may need to be charged.
· Check the door and be sure it is completely closed.
Unit noisy
· Check fan blades to see if they are contacting anything.
· Maintain 7 inches of clearance from the wall.
· Check for loose part or mounting.
· Keep the tubing free from any contact to avoid rattle.
Condensation on
cabinet exterior
and/or floor
· Reduce humidity where the unit is installed.
· Repair or replace the gasket on the door.