beautypg.com

Troubleshooting – Nor-Lake AdvantEDGE Pizza Prep Tables User Manual

Page 3

background image

08/13 Rev. B 146574

3

TROUBLESHOOTING

Problem

Remedy

Compressor will
not start

· Check the power cord and make sure it is plugged in.

· Check the temperature controller. If it is in the “OFF”

position, turn it clockwise to set a desired temperature.

Poor performance

· Move the unit from direct sunlight.

· Move the unit away from heating devices.

· Install the unit in a well ventilated place,

with at least 7 inches of clearance on all sides.

· Clean the condenser if heavy dust is collected.

· Clear contents from blocking the air duct.

· Check the temperature controller for incorrect setting.

· Check the refrigerant level, it may need to be charged.

· Check the door and be sure it is completely closed.

Unit noisy

· Check fan blades to see if they are contacting anything.

· Maintain 7 inches of clearance from the wall.

· Check for loose part or mounting.

· Keep the tubing free from any contact to avoid rattle.

Condensation on
cabinet exterior
and/or floor

· Reduce humidity where the unit is installed.

· Repair or replace the gasket on the door.