2.3 GENERAL

INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ENSURE ITS OPERATION
AND QUALITY!

RATES AND EFFICIENCIES

NATURAL GAS

PROPANE

Altitude

0 - 2,000*

0 - 2,000*

Maximum input

6,000

6,000

Minimum Inlet Gas Supply Pressure

4.5” Water Column

11” Water Column

Maximum Inlet Gas Supply Pressure

7” Water Column

13” Water Column

Manifold Pressure Under Flow Conditions

3.5” Water Column

10” Water Column

* When the appliance is installed at elevations above 2,000ft and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed altitude input rating shall be reduced at the rate of 4%
for each additional 1,000ft.

This appliance is only for use with the type of gas indicated on the rating plate. For rating plate location,
see either “INSTALLATION OVERVIEW” or “RATING PLATE INFORMATION” section. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.

Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.

The rating label is located under the control panel and is chained to the appliance. DO NOT REMOVE.

This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.

2.4 RATING PLATE INFORMATION

CERTIFIED UNDER : ANSI Z21.11.2a-2008 VOLUME II, UNVENTED ROOM HEATER

THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME,
WHERE NOT PROHIBITED BY LOCAL CODES. THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON
THE RATING PLATE. THIS APPLIANCE IS NOT FIELD CONVERTIBLE FOR USE WITH OTHER GASES.
THIS IS A GAS-FIRED UNVENTED ROOM HEATER THAT REQUIRES ADEQUATE COMBUSTION AND VENTILATION AIR.

ALTITUDE

INPUT

MANIFOLD PRESSURE: 3.5" WATER COLUMN

MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN

MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN

MANIFOLD PRESSURE: 10" WATER COLUMN

MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN

MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN

0-2000FT (0-1370m)
6,000 BTU/h

0-2000FT (0-1370m)

6,000 BTU/h

GVFT8N

MODEL

GVFT8P

MODEL

W385-0480 / C

GVFT8

WARNING:

DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAME. DO NOT USE ACCESSORIES

NOT APPROVED FOR USE WITH THIS APPLIANCE. IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTAINANCE CAN
CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED WITH THIS
APPLIANCE. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
TOP 18” FLOOR

8”

SIDES 1”

BACK 0”

TOP, SIDES & BACK AS PER ABOVE. FOR FINISHING
MATERIAL, SEE OWNERS MANUAL.

SERIAL NUMBER:

ELECTRICAL RATING: 115v 0.82AMP, 60HZ

(NATURAL GAS)

(PROPANE)

CONTROL: COPRECI T15

CONTROL: COPRECI T15

OXY PROTECTOR SIT: #9099

OXY PROTECTOR SIT: #9266

WOLF STEEL LTD.
24 NAPOLEON ROAD. BARRIE, ONTARIO L4M 0G8 CANADA

9700539 (WSL)

4001657 (NGZ)

4001658 (NAC)

4001659 (WUSA)

SAMPLE

SAMPLE

SAMPLE

TLY LOCATED, MANUF

FOR USE WITH THE TYP

SE WITH OTHER GASE

E COMBUSTION A

DE

UT

LUM

COLUMN

COLUMN

MANIFOLD P

NIMUM SU

MAXIMUM SUP

0-200
6,

LE

GVFT

EL

APPLIANCE, WHICH WILL C

OPER INSTALLATION

RY OR LOSS OF LIFE. REFER

MUST BE PERFORMED BY A

MATERIALS

0

ABOVE. FOR FINISHING

ANUAL.

G: 115v 0.82AMP, 60H

(PROPA

ECI T15

CONTROL: C

99

OXY PR