If the supply cord appears to be damaged, do not attempt to operate unit. Contact a
service agent or qualified electrician to repair.
!
WARNING:
This appliance is equipped with a three-prong or four-prong (grounding) plug for your
protection against shock hazard and should be plugged directly into a properly
grounded receptacle. Do not cut or remove the grounding prong from this plug.
!
WARNING
DOMESTIC:
This appliance must be properly grounded at time of installation. Failure to ensure
that this equipment is properly grounded can result in electrocution, dismemberment
or fatal injury.
!
WARNING:
GROUNDING INSTRUCTIONS
• Oven MUST be grounded.
• Grounding reduces risk of electric shock by providing an escape wire for the electric current if an electrical short
occurs. This oven is equipped with a cord having a grounding plug. The plug must be plugged into an outlet that
is properly installed and grounded.
• Consult a qualified electrician or serviceman if grounding instructions are not completely understood or if doubt
exists as to whether the oven is properly grounded.
• Do not use an extension cord. If the product power cord is too short, have a qualified electrician install an outlet
near the appliance. This oven should be plugged into a separate circuit with the electrical rating as provided in
product specifications.
ELECTRICAL CODE REFERENCE
IN USA
When installed, this appliance must be electrically grounded and its installation must comply with the National
Electric Code, ANSI-NFPA 70, latest edition, the Manufacturer’s Installation Instructions, and applicable municipal
building codes.
IN CANADA
All electrical connections are to be made in accordance with CSA C22.1 – Canadian Electrical Code Part 1 and/or
local codes.
ALL OTHER COUTRIES
Local electrical codes will prevail.
1. All pole disconnection switch 3mm open contact distance.
2. To prevent electrical shock, an equal potential bonding ground-lug is provided in the back. This allows the
oven to be connected to an external bonding system.
3. When used as a double-stack (if applicable) and each oven has its own disconnection switch, all switches
should be closed together.
VENTILATION
Ventilation is not required but local codes prevail. These are the “authority having jurisdiction” as stated by the
NATIONAL FIRE PROTECTION ASSOCIATION, INC. in NFPA 96, latest edition.