16 Regenera-

ting/reheating

Setting of humidity pulsing. Press temperature key and turn switch to
change setting. The value indicates the number of seconds between each
injection into the oven chamber. If the value is increased, less humidity
is added to the oven chamber, if the value is reduced, more humidity is
added (factory setting is every 8 seconds).

17 Injection

interval 1

Combi steaming 1: See 16 (factory setting is every 12 seconds)

18 Injection

interval 2

Combi steaming 2: See 16 (factory setting is every 5 seconds)

19 Save all

Press ALARM to make a backup of all settings in all modes and
Programmes.

20 Retrieve all

Press ALARM to retrieve all settings saved in all modes and Programmes.

21 Retrieve ori-

ginal menu

Press ALARM and retrieve all Programmes preset by the manufacturer. In
step display, choose which program (0 – 4) to retrieve and press ALARM.

22 Interval screen

Interval of seconds before interval screen becomes active. 0 = 0 sec. / 1
= 10 sec. / 2 = 30 sec. / 3 = 60 sec./ 4 = 180 sec. / 5 = 600 sec.
Change by pressing STEP.

23 Language

Change by pressing STEP (1 – 4).

24 SW update

Updating of software. Special memory key required. Contact your local