beautypg.com

Program selections (pl #01-pl #07), Pl #01 – control settings, Section v program selections (pl #01-pl #07) – American Dryer Corp. Phase 7.4.2 DMC None User Manual

Page 16

background image

14

SECTION V

PROGRAM SELECTIONS (PL #01-PL #07)

PL #01 – CONTROL SETTINGS

SELECT LANGUAGE

This location determines in what language (various available) ALL messages will be displayed.

SELECT TEMP SCALE

Temperature-related programs are programmable to be operated in either Fahrenheit (°F) or Celsius (°C). The
temperature scale selection is made in “PL #01 TEMP SCALE”. Programs affected are:

1. Temperature Display Mode

2. Drying Temperatures

3. Cool Down Temperatures

IMPORTANT: When changing the temperature conversion status from Fahrenheit to Celsius, or vice

versa, ALL the temperatures will be changed accordingly. The Phase 7 dual
microprocessor controller (DMC) computer automatically calculates and converts
the temperatures in these programs to the previously set value. For example,
when changing from °F to °C, if the drying temperature was set for 150°F, the
Phase 7 DMC (computer) will change to 66°C (+/- 1°Celsius).

SELECT BUZZER MODE

This location determines whether the buzzer will sound at the end of each Wrinkle Guard Cycle. This option is
toggled ON/OFF. Refer to the Wrinkle Guard description in Section III for an explanation of Wrinkle Guard
functionality.

BEEP COUNT 1 TO 9 BEEPS

If the Buzzer Mode is set to “ON”, this location determines how many times the buzzer will beep at the end of
a Wrinkle Guard Cycle.

SELECT DRY MODE

This option determines whether the dryer operates in Free Mode or Coin Mode.