Resetting to the factory default settings, As described in – Axis Communications 221 User Manual
Page 39

39
AXIS 221 - System Options
Resetting to the Factory Default Settings
To reset the camera to the original factory default settings, go to the System Options >
Maintenance web page (as described in Maintenance, on page 37) or use the Reset button
on the rear of the camera (see the illustration on page 6) as described below:
Using the Reset Button
To reset the camera to the factory default settings using the Reset Button:
1. Disconnect the power adapter, or the network cable if using PoE.
2. Press and hold the Reset button while reconnecting power.
3. Keep the Reset button pressed until the Status Indicator color changes to amber
(which may take up to 15 seconds).
4. Release the Reset button.
5. When the Status Indicator changes to Green (which may take up to 1 minute), the
process is complete and the camera has been reset. The unit will now have the
default IP address 192.168.0.90