beautypg.com

Electrical diagram bfc 28-60 – A.O. Smith BFC - 50 User Manual

Page 5

background image

Cyclone BFC

Electrical diagram BFC 28-60

Cyclone BFC

Electrical diagram BFC 80-100

TERMINAL STRIP CONNECTIONS

Earth

N

Neutral

L

Phase input of controller

L1 Phase output of isolating

transformer ( secundary side)

L2 Phase input of isolating

transformer ( primary side)

L3 Phase input of program-

controlled pump

L4 Phase input of frequency

controller

L5 Phase input of continuous pump

COMPONENTS
A

Controller

B

Ionisation rod

C

Glow ignitor

D

Gas control

E

Burner earth connection

F

External ON-mode switch

G

Program-controlled pump

H

External error-signal

J

Isolating transformer

K

Double-pole mains switch

L

Controller 0/1 switch

M Display/Flat cable
N

Fan

O

Temperaturesensor

(T2-bottom of tank)

P

Dummy

Q

Temperaturesensor

(T1-top of tank)

R

Selection resistor

S

Pressure switch

T

Potentiostat

U

Frequency controller

V

Argus-link interface

W Electric anodes
X

Signaling for electric anodes

Y

Mains choke and EMC filter

CONTROLLER CONNECTIONS
J2 Connector for power supply

to controller

J19 Connector for external error-signal
J20 Connector for gas-control
J21 Connector for program

controlled pump

J36 Connector for display

to controller

J39 Connector for fan controlled signal
JP2 Connector for ionisation rod and

glow ignitor

JP3 Connector for temperature

sensor T2

JP4 Connector for dummy
JP5 Connector for temperature

sensor T1

JP6 Connector for selection resistor,

pressure switch and anode

signaling

JP8 Connector for extra

ON-mode switch

F1 Fuse
F3 Fuse

TERMINAL STRIP CONNECTIONS

Earth

N Neutral
L1 Phase input of controller
L2 Phase input of isolating

transformer (primary side)

L3 Phase output of isolating

transformer (secondary side)

L4 Phase input of program-controlled

pump

L5 Phase input of continuous pump

COMPONENTS
A Controller
B

Ionisation rod

C

Glow igniter

D Gas control
E

Burner earth connection

F

Extra ON mode switch

G Continuous pump
H Program-controlled pump
J

Extra error signal

K Isolating transformer
L

Double-pole mains switch

M ON/OFF switch control
N Display/Flat cable
O Fan
P

Temperature sensor

(T2 - bottom of tank)

Q Dummy
R

Temperature sensor

(T1 - top of tank)

S

Selection resistor

T

Pressure switch

CONTROLLER CONNECTIONS
J1 Connector for display to controller
J2 Connector for power supply to

controller

J19 Connector for extra error signal
J20 Connector for gas control
J21 Connector for program-

controlled pump

J24 Connector for fan
JP2 Connector for ionisation rod and

glow igniter

JP3 Connector for temperature

sensor T2

JP4 Connector for dummy
JP5 Connector for temperature

sensor T1

JP6 Connector for selection resistor

and pressure switch

JP8 Connector for extra

ON mode switch

F1 Fuse
F2 Fuse

Colour cables
1 = brown
2 = blue
3 = yellow/green
4 = black
5 = white (flat cable)
6 = grey/beige

Colour cables
1 = brown
2 = blue
3 = yellow/green
4 = black
5 = white (flat cable)
6 = grey/beige
7 = red
8 = green

This manual is related to the following products: