Outdoor unit maintenance remote control – Panasonic 36PEF1U6 User Manual

Page 186

background image

5-8

5. Outdoor unit maintenance remote control

List of Item Codes

r

e

t

e

m

a

r

a

P

e

d

o

c

m

e

t

I

01

Control system schedule

02

Control system schedule

03

Control system schedule

04

Snowfall sensor operation

0 = No sensor, control performed
1 = No sensor, control not performed

Do not set

Do not set

Do not set

Do not set

Do not set

Do not set

Do not set

Do not set

Do not set

Do not set

Do not set

Do not set

Do not set

Do not set

Do not set

Do not set

2 = Sensor present, control performed
3 = Sensor present, control not performed

05

Outdoor fan quiet mode

Do not set

06

Defrost fan speed selection

Do not set

07

Ignore capacity

0 = Disabled

1 = Ignores capacity ratio

08

Control system schedule

09

Control system schedule

0A

Control system schedule

0b

Control system schedule

0C

Forced operation of

0 = Disabled

indoor unit drain pump

1 = During cooling only, 2 hours stopped + 20 minutes operating
(regardless of whether the unit is running or stopped)
2 = During cooling only, 4 hours stopped + 20 minutes operating
(regardless of whether the unit is running or stopped)
3 = At all times, 4 hours stopped + 20 minutes operating
4 = At all times, 2 hours stopped + 20 minutes operating

0d

Odor countermeasure when

Do not set

indoor cooling thermostat is OFF

y

l

n

o

l

o

o

C

=

1

p

m

u

p

t

a

e

H

=

0

y

l

n

o

l

o

o

C

E

0

0F

Control system schedule

10

Control system schedule

11

Multi-floor installation

12

External Electronic Expansion Valve Kit

13

Control system schedule

4E

Test mode 1

4F

Test mode 2

%

0

6

1

.

.

.

%

0

0

1

.

.

.

%

5

4

,

%

0

4

1

d

n

a

m

e

D

0

5

%

0

6

1

.

.

.

%

0

0

1

.

.

.

%

5

4

,

%

0

4

2

d

n

a

m

e

D

1

5

52

Current control level

40%, 45% ... 100% ... 160%, –1 (normal: at shipment from factory)

53

Control system schedule

55

Do not set

Control system schedule

54

7

5

8

5

9

5

A

5

B

5

6

5

* Figures in parentheses indicate the data at the time of shipment from the factory.

0 = No

1 = Yes

Control system schedule

Control system schedule

Do not set

Control system schedule

Do not set

Control system schedule

Do not set

Control system schedule

Do not set

Control system schedule

Do not set

Control system schedule

5