9. ACTUAL OPERATION

NOTE

The results of

M10: Auto Zero Exe

can be

displayed using

M11: Magflow Zero

. Alterna-

tively, if the results of the automatic zero
adjustment exceed the rated value, the warn-
ing

82: Auto Zero Wng

will be displayed.

9.1.2

Zero Adjustment via External Status Input

This section describes the procedure for zero adjustment via external status input. (For
more details regarding external status input, refer to Chapter 6: Parameter Description.)

CAUTION

In certain cases where the multiple range function is being used with other status
inputs, it may not be possible to perform settings for automatic zero adjustment.
For more details, refer to the description of multiple ranges from Chapter 6:
Parameter Description.

In order to carry out zero adjustment via external status input, it will be necessary to set
“Ext Auto Zero” using either F12: SI1 Function

or F13: SI2 Function

. The parameter

F12: SI1 Function

will be used in the following description.

Once in Setting Mode, use the

switch to

move the cursor to item F: Status Function

.

Touch the

switch to access Sub-item

Parameter Search Mode.

Touch the

switch twice to move the cursor

to F12: SI1 Function

.

The cursor has been moved to F12: SI1 Function

in this screen. (Sub-item selection screen (E))

Touch the

switch to access Parameter

Replacement Mode.

Touch the

switch twice to move the cursor

to “Ext Auto Zero”.

F0902-1.EPS

Setting Mode

Major item

parameter

Setting Mode

E:Pulse Set

F:Status Function

G:Alarm

F12:SI1 Function
No Function

No Function

0% Signal Lock

Major item

Sub-item
parameter

Major item

Sub-item
selection (E)

F:Status Function

41:Bi Direction Hys

10:SO1 Function

11:SO2 Function

F:Status Function

11:SO2 Function

12:SI1 Function

13:SI2 Function

X2

X2

Sub-item

Parameter

Search Mode

Parameter

Replacement

(execute) Mode

Start:

Major Item

Parameter